Generel Data / model | 07/1320 | 08/1170 | 10/1070 | 13/850 |
---|---|---|---|---|
Recoverable thermal output ¹ | 214 - 356 kW | |||
Fuel cosumption (Hu=10,0 kW/Nm³) | 31,6 Nm³/h | |||
Power requirement (kW) | 3,5 kW | |||
BUS-System | Modbus TCP | |||
Remote maintenanceTCP/IP | yes | |||
Engine | ||||
Type | R6 | |||
Engine displacement | 8,4 L | |||
Engine Type | Naturally aspirated | |||
Brennstoffeinsatz ² | 316 kW | |||
RPM | 1800 min -1 | |||
ISO standard power (mech.) ² | 120 kW | |||
Engine cooling water heat quantity | 111 kW | |||
Exhaust gas heat capacity 110 °C | 65 kW | |||
Efficieny Thermal ² | 55,7% | |||
Efficieny Combined (el. + th.) ² | 93,7% | |||
Engine oil | semi-synthetic | |||
Lubrication oil consumption | 60 g/Bh | |||
Filling capacity lubricant (max.) | 20 + 150 L | |||
Compressor | ||||
Manufacturer | Atlas Copco | |||
Heat recovery compressor | 103 kW | |||
RPM, min¯¹ | 4150 | 3800 | 3500 | 2800 |
Outlet pressure, barg ³ | 7 | 8 | 10 | 13 |
Free air delivery (FAD), m³/min ³ | 22 | 19,5 | 17,8 | 14,2 |
Modulation / power control | 60% - 100% | |||
Compressed air connection | DN 80 PN 16 | |||
Gas supply | ||||
Gas train | Nach DIN | |||
Interface Gas | DN 40 (1,5") | |||
Gas flow pressure | 30 - 100 mbar | |||
Air supply | ||||
Combustion air mass flow | 405 kg/h | |||
Air temperature | 25°C | |||
Exhaust | ||||
Interface Exhaust | DN 125 | |||
TA-Luft | yes | |||
Exhaust temperature | 640°C | |||
Condensate mass flow | 46 kg/h | |||
Max. permissible back pressure | < 15 mbar | |||
Flow rate, dry | 349 Nm³/h | |||
Mass flow, wet | 428 kg/h | |||
Hydraulic integration | ||||
Interface inlet/outlet | DN 50 (2") | |||
Norm in-/outlet temperatur | 70 / 90°C | |||
Standard flow rate | 11 m³/h | |||
Heating water pressure | 2,5 bar (ü) | |||
Dimensions / Weight | ||||
Dimensions (LxWxH) | 2720x1100x2020 mm | |||
Weight Module (w/o operating fluids) | 2800 kg | |||
Dimensions housing (LxWxH) | 3000x1300x2100 mm | |||
Weight housing | ca. 634 kg | |||
Dimensions cabinet (LxWxH) | 800x300x1200 mm | |||
Weight cabinet | 120 kg | |||
Recommended concrete strength | C20/25 | |||
Payload, qk | 3,5 kN/m² | |||
Noise emissions (incl. standard silencer) | ||||
Unit 1 m / 10 m | 75 / 65 dB(A) | |||
Exhaust gas stack 10 m | 67 dB(A) | |||
Exh. emissions with catalytic converter | ||||
NOX | < 250 mg/Nm³ | |||
CO | < 250 mg/Nm³ | |||
HCHO | < 5 mg/Nm³ | |||
Protection class | ||||
Unit | IP 23 | |||
Unit with housing | IP 53 | |||
Control cabinet | IP 55 | |||
Options | ||||
Housing | yes | |||
Additional silencer | yes | |||
Emergency cooler | yes | |||
Gas warning system | yes | |||
Knock control | yes | |||
Gross calorific value | yes | |||
Additional lubrication oil tank | yes | |||
LTE / UMTS-modul | yes | |||
BUS-converter | yes | |||
Heat meter (calibrated) | yes | |||
Neutralisation plant | yes | |||
Compressed air flow meter | yes | |||
Containerised solution | yes | |||
Remote control | yes | |||
Catalyst technology for oil-free air | yes | |||
Directly heated adsorption dryers | yes | |||
Master Control readynes | yes | |||
Contribution, installation, commisioning | yes |
¹ with a tolerance of ±7%; ² acc. to ISO 3046-1; ³ acc. to ISO 1217, Anh. D.